A9-30-10 220-230V 50Hz / 230-240V 60HzGeneral Information
Extended Product Type:
A9-30-10 220-230V 50Hz / 230-240V 60Hz
Product ID:
1SBL141001R8010
EAN:
3471522031808
Catalog Description:
A9-30-10 220-230V 50Hz / 230-240V 60Hz Contactor
Long Description:
A 9 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.
Categories
Products »
Low Voltage Products and Systems
»
Control Products
»
Contactors
»
Across the Line Contactors
Ordering
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85364900
Replacement Product ID (NEW):
1SBL131001R8010
Popular Downloads
Data Sheet, Technical Information:
1SBC100122C0202_Ch02
Instructions and Manuals:
FPTC407721P0001
Dimensions
Product Net Width:
44
mm
Product Net Depth / Length:
74
mm
Product Net Height:
74
mm
Product Net Weight:
0.34
kg
Technical
Number of Main Contacts NO:
3
Number of Main Contacts NC:
0
Number of Auxiliary Contacts NO:
1
Number of Auxiliary Contacts NC:
0
Standards:
Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1, EN 60 947-1 and amendment 2 to IEC 947-4-1
Rated Operational Voltage:
Main Circuit 690 V
Rated Frequency (f):
Supply Circuit 50 60 Hz
Conventional Free-air Thermal Current (I
th
):
acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
Rated Operational Current AC-1 (I
e
):
(690 V) 40 °C 25
(690 V) 55 °C 22
(690 V) 70 °C 18
Rated Operational Current AC-3 (I
e
):
(415 V) 55 °C 9 A
(440 V) 55 °C 9 A
(500 V) 55 °C 9 A
(690 V) 55 °C 7 A
(380 / 400 V) 55 °C 9 A
(220 / 230 / 240 V) 55 °C 9
Rated Operational Power AC-3 (P
e
):
(415 V) 4 kW
(440 V) 4 kW
(500 V) 5.5 kW
(690 V) 5.5 kW
(380 / 400 V) 4 kW
(220 / 230 / 240 V) 2.2 kW
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
8 x Ie AC-3
Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
10 x Ie AC-3
Rated Operational Current AC-15 (I
e
):
(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(380 / 400 V) 3 A
Short-Circuit Protective Devices:
Auxiliary Circuit - gG Type Fuses 10 A
gG Type Fuses 25 A
Maximum Breaking Capacity:
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
Maximum Electrical Switching Frequency:
(AC-1) 600 cycles per hour
(AC-2 / AC-4) 300 cycles per hour
(AC-3) 1200 cycles per hour
Rated Operational Current DC-13 (I
e
):
(24 V) 6 / 144 A
(48 V) 2.8 / 134 A
(72 V) 2 / 144 A
(125 V) 1.1 / 138 A
(250 V) 0.55 / 138 A
Rated Insulation Voltage (U
i
):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (U
imp
):
8 kV
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Rated Control Circuit Voltage (U
c
):
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
Coil Consumption:
Average Holding Value 50 / 60 Hz 8 2 V·A
Average Pull-in Value 50 Hz 74 V·A
Average Pull-in Value 60 Hz 70 V·A
Operate Time:
Between Coil De-energization and NO Contact Opening 4 ... 11 ms
Between Coil Energization and NO Contact Closing 10 ... 26 ms
Connecting Capacity Main Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Connecting Capacity Auxiliary Circuit:
Flexible with Cable End 0.75 ... 2.5 mm²
Rigid Cable 1 ... 4 mm²
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Connecting Terminals (delivered in open position) Main Poles:
M 3.5 (+,-) pozidriv 2 screws with cable clamp
Terminal Type:
Screw Terminals
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C
Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic Withstand:
acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
Maximum Operating Altitude Permissible:
3000 m
Resistance to Shock acc. to IEC 60068-2-27:
Closed, Shock Direction: B1 10 K40
Open, Shock Direction: B1 5 K40
Shock Direction: A 20 K40
Shock Direction: B2 15 K40
Shock Direction: C1 20 K40
Shock Direction: C2 20 K40
RoHS Status:
Following EU Directive 2011/65/EU
Certificates and Declarations (Document Number)
BV Certificate:
BV_2634H07559E0
CB Certificate:
CB_CN44759
CCC Certificate:
CCC_2018010304059156
CCC_2004010309130463
CQC Certificate:
CQC2013010304615753
CQC2018010304059156
CQC2004010309130463
CSA Certificate:
CSA_1041746
Declaration of Conformity - CCC:
2020980304001607
2020980304001616
2020980304001229
Declaration of Conformity - CE:
1SBD250801U1000
DNV Certificate:
DNV-GL_TAE00000TX
DNV GL Certificate:
DNV-GL_TAE00000TX
EAC Certificate:
EAC_RU C-FR ME77 B03599
Environmental Information:
1SBD250001E1004
Instructions and Manuals:
FPTC407721P0001
LOVAG Certificate:
LOVAG_FR97037
LR Certificate:
LRS_9830011E4
RINA Certificate:
RINA_ELE172319XG001
RMRS Certificate:
RMRS_0507015250
RoHS Information:
1SBD250801U1000
UL Certificate:
UL_20160205-E312527-10-2
UL Listing Card:
UL_E312527
Container Information
Package Level 1 Units:
1 piece
Package Level 1 Width:
78 mm
Package Level 1 Depth / Length:
76 mm
Package Level 1 Height:
47 mm
Package Level 1 Gross Weight:
0.34 kg
Package Level 1 EAN:
3471522031808
Package Level 2 Units:
box 63 piece
Package Level 2 Width:
300 mm
Package Level 2 Depth / Length:
245 mm
Package Level 2 Height:
308 mm
Package Level 2 Gross Weight:
21.42 kg
Package Level 3 Units:
1512 piece
Classifications
Object Classification Code:
Q
ETIM 4:
EC000066 - Magnet contactor, AC-switching
ETIM 5:
EC000066 - Magnet contactor, AC-switching
ETIM 6:
EC000066 - Power contactor, AC switching
ETIM 7:
EC000066 - Power contactor, AC switching
eClass:
V11.0 : 27371003
UNSPSC:
39121529
E-Number (Finland):
3709216